30J-P1 PID
All Gas Types Available
• Flexible output options
• Addressable or stand alone
• Hyper terminal communications rs232 line data and set up with 232 adapter
• Data logging
• Optional alarm relays
• Optional status display
• Robust and weather-proof
The 30J-PID (photoionization detector) is used to detect a broad range of volatile organic compounds in the low ranges of 0 to 50ppm and 0 to1000ppm. The unit provides standard 4~20mA and CAN bus digital outputs. Its enclosure has been designed to allow quick and easy access to its interior by adjustment of two allen screws, this factor is a major consideration when large system service and calibrations are being carried out. The detector is robust and weather-proof with improved response times due to the four mounting spacers allowing increased air movement around the detector these spacers also improve the mounting of the unit particularly on circular pillars typically found in carparks.
Specifications
Safe Area Detector Head / Junction B ox Assembly Specification Sheet - ref C1506-B
Power Supply - 15 to 30vDC 24v nominal
Outputs - 3 wire - analog 4~20mA / 4 wire - CAN bus
Relays (optional) - Low alarm S .P.C.O 0.5A @30vDC / High alarm S .P.C.O / Fault alarm S.P.C.O / over-range
Inhibit option during servicing - Logging
Intervals - one minute to one hour
Storage - 2,880 readings
Temperature -15˚C to 55˚C
Humidity - 0˚C to 99% RH - non condensing