Particle Impact Noise Detection
PIND BW-LPD-DAQ4000
Computer based controller with predefined MIL-STD test sequences stored (New)
Create unlimited custom tests with multiple vibration frequencies and acceleration and other parameters to meet unique requirements (New)
Easily store and recall custom test (New)
Continuous on screen display of test frequency, vibration level, etc.
A custom shaker capable of testing packages up to 5kg/10lbs at 20gs (See BW-LPD-DAQ-4000HD pages)
A custom test platen with up to 5 particle detection sensors (New)
On screen monitoring of signals created by loose particles
On screen indicator signals particle detections
Audio monitoring of signals created by loose particles
Stops the test when particle noise threshold is exceeded (user selectable)
Easily store and recall test results (New)
Supports both fully automatic and manual operation modes
Sensitivity Test Unit (STU) provided to verify MIL-STD compliance