Cylinder|Ultrasonic Sensors|for industrial use
- Ultrasonic Proximity Sensor 9.449" ~ 157.48" (240mm ~ 4000mm)
Ultrasonic waves are used to enable stable detection of transparent objects, such as transparent films, glass bottles, plastic bottles, and plate glass, using Through-beam or Reflective Sensors.
Features:
High-precision detection with a wide range of measurements.
Four types of Sensors are available with maximum sensing distances of 0.5 m, 2 m, 4 m, and 6 m. With the 0.5-m type, a repeat accuracy of 1 mm or better has been achieved.
The Sensor is ultrasonic, so it is not affected by the color of objects.
A variety of materials can be measured, including transparent and reflective objects. Measurements are performed with no contact, so even highly-viscous liquids are no problem.
A setting plug with a temperature compensation function makes it easy to set the sensing range.
The sensing range can be set by the Setting Plug, which is included with the Sensor. No special controller is required. The Setting Plug’s built-in temperature sensor provides superior temperature characteristics of ±1% FS.
The mutual interference prevention function allows up to five Sensors to be used in close proximity.
Ratings/Characteristics
Item
|
|
|
E4PA-LS400-M1-N
|
|
Sensing range
|
|
|
240 to 4,000 mm
|
|
Dead band distance
|
|
|
0 to 240 mm
|
|
Standard sensing object
|
100 × 100 mm flat plate
|
Applied frequency
|
|
|
Approx. 85 kHz
|
|
Response time
|
|
|
440 ms max.
|
|
Power supply voltage
|
10 to 30 VDC; ripple (p-p): 10% max.
|
Power consumption
|
1,800 mW max.
|
Analog output
|
Current output: 4 to 20 mA (Allowable load resistance: 500 Ω max.)Voltage output: 0 to 10 V (1,000 Ω min.)
|
Protective circuit
|
Load short-circuit protection, mutual interference prevention
|
Mutual interferenceprevention cycle time
|
|
|
77 ms
|
|
Linearity
|
±1% FS max.
|
Repeat accuracy *
|
0.1% FS max.
|
Temperature influence
|
±1% FS of output value at +23°C in the temperature range of -10 to 55°C
|
Voltage influence
|
±5% FS max. within rated power supply voltage range
|
Ambient temperature
|
Operating: -10 to 55°C (with no icing or condensation)Storage: -40 to 85°C (with no icing or condensation)
|
Ambient humidity
|
Operating and storage: 35% to 85% (with no condensation)
|
Insulation resistance
|
50 MΩ min. (at 500 VDC) between current-carrying parts and case
|
Dielectric strength
|
1,000 VAC (50/60 Hz) for 1 min between current-carrying parts and case
|
Vibration resistance
|
Destruction: 10 to 55 Hz, 1-mm double amplitude for 2 hours each in X, Y, and Z directions
|
Shock resistance
|
Destruction: 300 m/s2 three times each in X, Y, and Z directions
|
Connection method
|
5-conductor connector
|
Degree of protection
|
IEC60529: IP65
|
Weight (packed)
|
|
Approx. 320 g
|
|
Materials
|
Case: Stainless steel (SUS303)Sensing surface: PBT resin, polyurethane, glass epoxy resinClamping nut: Stainless steel (SUS303)
|
Accessories
|
Operation Manual
|
* Values are given one hour after power-up. The outputs may fluctuate due to external disturbances.