Micro Motion FDM Fork Density Meter
Micro Motion FDM Fork Density Meter
A direct-insertion Fork Density Meter, that offers installation flexibility with continuous, real-time density and concentration measurement in pipelines, bypass loops and tanks.
Specs
Density accuracy
±1,0 kg/m3(±0,001 g/cm3)
Operating density range
0-3000 kg/m3(0-3 g/cm3)
Operating temperature range – short stem
–50 °C a +200 °C (–58 °F a +392 °F)
Operating temperature range – long stem
–40 °C a +150 °C (–40 °F a +302 °F)
Materials
Wetted parts – short-stem meter:
304 or 316L stainless steel, Alloy C22, Titanium, or Zirconium
Wetted parts – long-stem meter:
Alloy C22 for stem lengths up to 2 m (6.5 ft) long
316L stainless steel for meters up to 4 m (13 ft) long
Tine finish:
Standard, DLC (Diamond-Like Carbon) coated, or electro-polished
Transmitter housing:
Polyurethane-painted aluminum or 316L stainless steel
Local display (optional)
- Segmented two-line LCD screen.
- Can be rotated on transmitter, in 90-degree increments, for ease of viewing
- Suitable for hazardous area operation.
- Optical switch controls for hazardous area configuration and display.
- Glass lens.
- Three-color LED indicates meter and alert status.
Display functions
- View process variables.
- View and acknowledge alerts.
- Configure mA and RS-485 outputs.
- Supports Known Density Verification (KDV).
- Supports multiple languages.
Transmitter output channels
- Available output channels (depending on the Electronics Interface option):
- One or two externally powered (passive) 4–20 mA outputs
- Channel A is 4–20 mA + HART
- Channel B is 4–20 mA
- One externally powered (passive) Time Period Signal (TPS)output
- One externally powered (passive) Discrete output
- One Modbus/RS-485 output Can also be ordered with a processor for use with a remote-mount 2700 FOUNDATION fieldbus transmitter
Meter approvals, calibrations, and certifications
- Agencies & types of approval available:
- ATEX
- CSA
- IECEx
Features
- Increase installation flexibility with continuous, real-time measurement in pipelines, bypass loops and tanks
- Choose from a wide range of corrosion-resistant materials for measuring density and concentration of critical chemicals
- Ensure friction reduction and improve coating immunity with Diamond-like Carbon (DLC) coating
- Accelerate verification of meter health and installation with internal diagnostics
- Support multiple simultaneous protocols for connection to DCS, PLC and flow computers
- Expand usage with a hazardous area-approved, head-mounted transmitter that supports local configuration and display
- Interact with our to learn more about our Dedicated Density and Viscosity Meters